Non-welded ASME Filters DA 400, Pressure filters, change-over

Description:

Pressure filters, change-over series DA 400 manufactured according to ASME Code and API Standard 614 are suitable for operating pressure up to 40 bar. Pressure peaks can be absorbed with a sufficient margin of safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation.
Filter finer than 40 µm should use throw-away elements made of paper or Interpor fleece (glass fibre).
Filter elements as fine as 5 µm (c) are available; finer filter elements on request. These filters can also be installed as suction filters.


Technical data:

temperature range - 10°C to + 80°C (for a short time + 100°C)
operating medium mineral oil, other media on request
max. operating pressure 40 bar
test pressure 58 bar
connection system SAE-flange connection 3000 PSI or ANSI-flange connection 300 PSI
housing material steel
sealing material Nitrile (NBR) or Viton (FPM), other materials on request
installation position vertical
bleeder connection NPT ½“ or ANSI ¾“ 300 PSI
drain connection dirt side NPT ½“ or ANSI ¾“ 300 PSI
drain connection clean side NPT ½“
volume tank 2x 4,3 l
calculation for IS21 according to ASME-Code Sec. VIII, Div.1