CCT 01 – Contamination Class Transmitter - Set

Description:

Inexpensive and reliable inline system to control contamination classes. It consists of the actual contamination class transmitter CCT 01 with integrated three-channel particle counter in combination with the particle flow sensor PFS 01.
Applicable for hydraulic and lubricating oils.
When using the CCT 01 as contamination class transmitter, the measurement signals received from the laser sensor are transformed into contamination classes and passed on as analogue output (4…20 mA).
The signals emitted accord the contamination classes based on ISO 4406:99 (³ 4 µm(c), ³ 6 µm(c), ³ 14 µm(c)).
The CCT 01 does not have keys, but using the USB-interface and a PC, it is possible to configure the device, set calibration values or transmit current or saved particle numbers. The data can be processed further from external computers.
The laser sensor PFS 01 is calibrated according to ISO 11171:99. Calibration values are preset for each CCT 01.
It is possible to save measurements in user-defined intervals. (up to 1000 measurements)
Suitable for installation in new or existing systems

Fields of application

Contamination monitoring at:
  • Different test stands for hydraulic components
  • Filter service devices
  • Wind energy plants
  • Mobile and stationary hydraulic systems in general
  • Technical data:

    Serial Interface USB (configuration)
    CAN-interface acc. ISO 11898, CAN 2.0A, CANopen compatible, M12-connector
    Dimensions 201 X 85 X 35 mm x mm x mm
    Weight 380g
    Output signals 3 x 4....20 mA

    PFS 01 – Lasersensor

    Technical data:

    Calibration of particle size ISO MTD in Öl ISO 11171:2000)
    Max. acceptable operating pressure ≤ 50 bar
    Max. oil temperature (short term) 70 °C
    Viscosity range 10.....400 mm2/s
    Ambient temperature 0....+ 45 °C
    Max. acceptable volume flow 50 l/ min.
    Connections Rohrleitungen 1“ oder ¾“
    Protection class IP 65
    Weight 1,5 kg