|
pressure filter, change-over | DU 63 |
|
|

| Description: Pressure filter of the series DU 63 are suitable for a working pressure up to 32 bar. The pressure peaks are absorbed by a sufficient margin of safety. Rotary slide valve which is integrated in the middle of the housing makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. These filters can be installed as suction-filters. The filter element consist of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to the inside. Filter finer than 40 μm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 μm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirt-retaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. Approvals according to TÜV, and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. The internal valve is integrated in the filter cover. After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter.
|  | Instruction manual | | Technical data: | | | | | temperature range: | - 10 °C to + 80 °C (for a short time + 100 °C) | | operating medium: | mineral oil, other media on request | | max. operating pressure: | 32 bar | | test pressure: | 64 bar | | connection system | thread connection according to ISO 228 | | housing material: | EN-GJS-400-18-LT | | sealing material: | Nitrile (NBR) or Viton (FPM), other materials on request | | installation position: | vertical | | mini-measuring connections: | G ½ | | evacuation-or bleeder connections: | G ½ | | volume tank: | 2x 0,65 l | | | | | | | | |
Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4).
|  | Data Sheet |  | Brochure |  | Clogging Indicator: | | visual AOR/AOC visual/electrical AE electronical VS1 electronical VS2 | |
|