Spin-on filter | WPL 45-260 |
|
|
|

|
Description:
In-line filter series WPL and WP-spin-on-cartridges are suitable for an operating pressure up to 145 PSI. They are appointed for mounting into pressure lines and return lines. the spin-on-cartridges, e.g. are directly screwed to hydrostatic drives. These series allow an easy maintaining with short operating interruption. After pollution the complete spin-on-cartridges has to be changed. The WPL-filter can alternatively be equipped with pressure switch and/or pressure gauge. The serie can be used for all mineral oils (hydraulic- and lubrication oils).
|
 |
Instruction manual |
| Technical data: |
|
|
|
| temperature range: |
+14°F to 230°F |
| operating medium: |
mineral oil, other media on request |
| max. operating pressure: |
145 PSI |
| test pressure: |
188 PSI |
| opening pressure by-pass valve forpressure filter: |
Δp 29 PSI |
| opening pressure by-pass valve forsuction filter: |
Δp 4 PSI |
| pressure switch: |
Δp 22 PSI see sheet-no. 1616 |
| pressure switch: |
Δp 3.6 PSI see sheet-no. 1616 |
| gaskets: |
Nitrile (NBR) |
|
|
|
|
|
|
Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no.34279-4).
|
 |
Data Sheet |
 |
Brochure |
 |
Clogging Indicator: |
|
visual O1
electrical E4
|
|
|