in-line filter | LF 2005-4005 |
|
|
|

|
Description:
In-line filters of the type LF2005-4005 are suitable for a working pressure up to 464 PSI. Pressurepeaks are absorbed with a sufficient margin of safety. The filter is mounted in such a waythat inlet and outlet are on the same level. It can be used as suctionfilter, pressure filter and return-line filter. The filter elementconsists of star-shaped, pleated filter material which is supported onthe inside by a perforated core tube and is bonded to the end caps witha high-quality a dhesive. The flow direction is from outside to inside. For cleaning (see special leaflet21070-4 and 34448-4) the mesh element respectively to change the glassfibre element remove the cover and take out the element. Filter finer than 40 μmshould use throw-away elements made of paper or Interpor fleece (glassfibre). Filter elements as fine as 5 μm(c) microns areavailable; finer filter elements on request. INTERNORMEN-Filter elements areknown as elements with a high intrinsic stability and an excellentfiltration capability, a high dirt retaining capacity and a longservice life. INTERNORMEN-Filter are suitable forall petroleum based fluids, HW-emulsions, most synthetic hydraulicfluids and lubrication oils Approvals according toTÜV, and the major „Shipyard ClassificationSocieties“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. andothers are possible.
|
 |
Instruction manual |
| Technical data: |
|
|
|
| temperature range: |
+ 14°F to + 176°F (for a short time + 212°F) |
| operating medium: |
mineral oil, other media on request |
| max. operating pressure: |
464 PSI |
| test pressure: |
900 PSI |
| connection system |
SAE-flange connection 3000 PSI |
| housing material: |
EN-GJS-400-18-LT |
| sealing material: |
Nitrile (NBR) or Viton (FPM), other materials on request |
| installation position: |
vertical |
| measuring connections: |
BSPP ¼ |
| evacuation-or bleeder connections: |
BSPP ½ |
| volume tank LF 2005: |
6 Gal |
| LF 3005: |
8 Gal |
| LF 4005: |
10 Gal |
|
|
|
|
|
|
|
|
Classification according to thePressure Equipment Directive 97/23/EC for mineral oil (fluid group 2)-article 3, paragraph 3. Classified under ATEX Directive94/9/EC according to specific application (see questionnaire sheet-no.34279-4).
|
 |
Data Sheet |
 |
Brochure |
 |
Clogging Indicator: |
|
visual OP
visual-electrical AE
visual-electrical OE
electronical VS1
electronical VS2
|
|