Home Imprint Sitemap Contact Addresses
Deutsch (Deutschland)English (United Kingdom)American EnglishFrench (Fr)Español(Spanish Formal International)Russian(RU)Chinese

Upcoming fairs

No current events.

in-line filter | LF 1950-2200 Print E-mail

in-line filter - LF 1950-2200

Description:

In-line filters of the type LF1950-2200 are suitable for a working pressure up to 464 PSI.
Pressure peaks are absorbed with asufficient margin of safety.
The filter is mounted in such a waythat inlet and outlet are on the same level. It can be used as suctionfilter, pressure filter and return-line filter. The filter elementconsist of star-shaped, pleated filter material which is supported onthe inside by a perforated core tube and is bonded to the end caps witha high-quality adhesive. The flow direction is from outside to theinside.
For cleaning (see special leaflet21070-4 resp. 39448-4) the mesh element respectively to change theglass fiber element remove the cover and take out the element.
Filter finer than 40 μmshould use throw-away elements made of paper or Interpor fleece (glassfiber). Filter elements as fine as 5 μm(c) are available; finerfilter elements on request.
INTERNORMEN-Filter elements areknown as elements with a high intrinsic stability and an excellentfiltration capability, a high dirt retaining capacity and a longservice life.
INTERNORMEN-Filter are suitable forall petroleum based fluids, HW-emulsions, most synthetic hydraulicfluids and lubrication oils
Approvals according toTÜV, and the major „Shipyard ClassificationSocieties“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. andothers are possible.
The internal valve is integrated inthe filter cover. After reaching the opening pressure the by-pass valvecauses that an unfiltered partial flow passes the filter.


folder_grey Instruction manual
Technical data:
temperature range: +14°F to +176°F (for a short time +212°C)
operating medium: mineral oil, other media on request
max. operating pressure: 464 PSI
test pressure: 900 PSI
connection system SAE-flange connection 3000 PSI
housing material: GGG 40.3
sealing material: Nitrile (NBR) or Viton (FPM),
other materials on request
installation position: vertical
mini-measuring connection:

¼ BSPP

evacuation-or bleeder-connection: ½ BSPP
volume tank: LF 1950: 5.7 Gal
LF 2200: 5.8 Gal
Classified under the PressureEquipment Directive 97/23/EC for mineral oil (fluid group 2), Article3, Para. 3.
Classified under ATEX Directive94/9/EC according to specific application (see questionnaire sheet-no.34279-4).
folder_grey Data Sheet
folder_grey Brochure
folder_man Clogging Indicator:

visual OP

visual-electrical AE

visual-electrical OE

electrical VS1

electrical VS2

 