Pressure filter, change-over | HDD 30 |
|
|
|

|
Description:
Duplex pressure filters with change-over valve type HDD are suitable for a working pressure up to 4568 PSI. The pressure peaks are absorbed by a sufficient margin of safety. Duplex filters can be serviced without interruption of operation. The upper part has a three-way-change-over valve which allows to change-over the flow from the dirty filter-side to the clean filterside without interrupting the operation. The change-over procedure does not lead to a cross sectional contraction. Prior to the change-over procedure a built-in pressure balance valve equalizes the housing pressure. After change-over the pressure balance valve has to to be closed again. The closed filter-side has to be air-bled by vent III respectively by vent IV. Then change filter element. After screw in the filter bowl the pressure balance has to be opened shortly and the just serviced filter-side has to be airbled. Filter elements are available down to a filter fineness of 4 μm(c). INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. INTERNORMEN-Filter elements are available with a pressure difference resistance up to p 2320 PSI and a rupture strength up to ∆p 3625 PSI.
|
 |
Instruction manual |
| Technical data: |
|
|
|
| temperature range: |
+14°F to +176°F (for a short time +212°F) |
| operating medium: |
mineral oil, other media on request |
| max. operating pressure: |
4568 PSI |
| test pressure: |
5945 PSI |
| connection system: |
thread connection |
| housing material: |
EN-GJS-400-18-LT; C-steel |
| sealing material: |
Nitrile (NBR) or Viton (FPM), other materials on request |
| installation position: |
vertical |
| air bleeding and mini-measuringconnection: |
BSPP ¼ |
| volume tank: |
2x .02 Gal. |
|
|
|
|
|
|
Einstufung nachDruckgeräterichtlinie 97/23/EG für Mineralöl(Fluidgruppe 2) - Artikel 3, Classified under the PressureEquipment Directive 97/23/EC for mineral oil (fluid group 2), Article3, Para. 3. Classified under ATEX Directive94/9/EC according to specific application (see questionnaire sheet-no.34279-4).
|
 |
Data Sheet |
 |
Brochure |
 |
Clogging Indicator |
|
visual AOR/AOC
visual-electrical AE
electronical VS1
electronical VS2
|
|
|