|
Pressure filter, change-over withvertical connecting line | DUV 1050-2050 |
|
|
|

|
Description:
Pressure filters, change-over series DUV 1050-2050 are suitable for operating pressure up to 464 PSI. Pressure peaks can be absorbed with a sufficient margin o safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter- side without interrupting operation. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to the inside. These filters can be installed as suction filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 μm should use throuw-away elements made of paper or Interpor fleece (glass fiber). Filter elements as fine as 5 μm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. Approvals according to TÜV, and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. The internal valve is integrated in the filter cover. After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter.
|
 |
Instruction manual |
| Technical data: |
|
|
|
| temperature range: |
+14°F to + 176°F (for a short time + 212°F) |
| operating medium: |
mineral oil, other media on request |
| max. operating pressure: |
464 PSI |
| test pressure: |
900 PSI |
| connection system |
SAE-flange connection 3000 PSI |
| housing material: |
EN-GJS-400-18-LT |
| switching housing-material: |
S355J2G3 |
| sealing material: |
Nitrile (NBR) or Viton (FPM), other materials on request |
| installation position: |
vertical |
| mini-measuring connections: |
¼ BSPP |
| evacuation-or bleeder connections: |
½ BSPP |
| volume tank DUV 1050: |
2x 3.6 Gal |
| DUV 2050: |
2x 6.3 Gal |
|
|
|
|
|
|
Classification according to the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2) -article 3, paragraph 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4).
|
 |
Data Sheet |
 |
Brochure |
 |
Clogging Indicator: |
|
visual-electrical AE
visual-elektrical OE
visual OP
electronical VS1
electronical VS2
|
|
|