Pressure filter, change-over | DU 63 |
|
|
|

|
Description:
Pressure filter of the series DU 63 are suitable for a working pressure up to 464 PSI. The pressure peaks are absorbed by a sufficient margin of safety. Rotary slide valve which is integrated in the middle of the housing makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. These filters can be installed assuction-filters. The filter element consist of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with ahigh-quality adhesive. The flow direction is from outside to the inside. Filter finer than 40 μm should use throw-away elements made of paper or Interpor fleece (glassfibre). Filter elements as fine as 5μm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirt-retaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. Approvals according to TÜV, and the major „Shipyard ClassificationSocieties“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. The internal valve is integrated in the filter cover. After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter.
|
 |
Instruction manual |
| Technical data: |
|
|
|
| temperature range: |
+14°F to +176°F (for a short time +212°F) |
| operating medium: |
mineral oil, other media on request |
| max. operating pressure: |
464 PSI |
| test pressure: |
900 PSI |
| connection system |
thread connection |
| housing material: |
EN-GJS-400-18-LT |
| sealing material: |
Nitrile (NBR) or Viton (FPM), other materials on request |
| installation position: |
vertical |
| mini-measuring connections: |
½ BSPP |
| evacuation-or bleeder connections: |
½ BSPP |
| volume tank: |
2x .17 Gal. |
|
|
|
|
|
|
|
|
Classified under the PressureEquipment Directive 97/23/EC for mineral oil (fluid group 2), Article3, Para. 3. Classified under ATEX Directive94/9/EC according to specific application (see questionnaire sheet-no.34279-4).
|
 |
Data Sheet |
 |
Brochure |
 |
Clogging Indicator: |
|
visual AOR/AOC
visual/electrical AE
electronical VS1
electronical VS2
|
|
|