Pressure filter change-over,according to ASME-code | DA 251-401 Print E-mail

pressure filter change-over,according to ASME-code - DA 251-401

Description:

Pressure filters, change-over series DA 251-401 are suitable for operating pressure up to 290 PSI.
Pressure peaks can be absorbed with a sufficient margin o safety.
Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation.
The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to the inside.
These filters can be installed as suction filters.
For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element.
Filter finer than 40 μm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 μm(c) are available; finer filter elements on request.
INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life.
INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils.
The inspection according to TÜV, according to ASME VIII Div.1 and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. If inspection is required please indicate in your order.


folder_grey Instruction manual
Technical data:
temperature range: + 14°F to + 176°F (for a short time + 212°F)
operating medium: mineral oil, other media on request
max. operating pressure: 290 PSI
test pressure acc. to PED 97/23/EC: 1,43 x operating pressure = 420 PSI
test pressure acc. to ASME VIIIDiv. 1: 1,3 x operating pressure = 377 PSI
test pressure acc. to API 614,Chapter 1: 1,5 x operating pressure = 435 PSI
connection system: SAE-flange connection 3000 PSI or
ANSI-flange connection 150 PSI
housing material: steel
sealing material: Nitrile (NBR) or Viton (FPM),
other materials on request
installation position: vertical
bleeder connection: NPT ½“ or ANSI ¾“ 150 PSI
drain connection dirt side: NPT ½“ or ANSI ¾“ 150 PSI
drain connection clean side: NPT ½“
volume tank:

DA 251 2x 0.79 Gal.
DA 400 2x 1.13 Gal.


Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3.
Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4)
folder_grey Data Sheet
folder_grey Brochure
folder_man Clogging Indicator:

visual-electrical AE

visual-elektrical OE

visual OP

visual AOR/AOC

electronical VS1

electronical VS2

 
FacebookYouTube