duplex filter with standard-return-line filter elements | DNR 1001-8201 |
|
|

| Description: Duplex filters of the series DNR 1001-8201 are suitable for a working pressure up to 16 bar. Pressure peaks can be absorbed with a sufficient margin of safety. Four mechanically connected change-over flaps enabling the change-over without service-interruption from the clean to the dirty filter-side. The filters can be installed as suction filter, pressure filter or return-line filter. The filter element consist of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to the inside. Filter finer than 40 μm should use throuw-away elements made of Interpor fleece (glass fibre). Filter elements as fine as 5 μm (c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirt-retaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. Approvals according to TÜV, and the mayor „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S.; P.R.S.;USS.R.S. and others are possible.
|  | Instruction manual: | | Technical data: | | | | | temperature range: | - 10 °C to + 80 °C (for a short time + 100 °C) | | operating medium: | mineral oil, other media on request | | max. operating pressure: | 16 bar | | test pressure: | 23 bar | | connection system | flange DIN 2633, 16 bar | | housing material: | C-steel | | sealing material: | Nitrile (NBR) or Viton (FPM), other materials on request | | installation position: | vertical | | mini-measuring connection: | G ¼ for screw coupling (mini-measuring) | | | | | | | | |
Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4).
|  | Data Sheet: |  | Brochure: |  | Clogging Indicator: | | visual OP visual-electrical AE visual-electrical OE electronical VS1 electronical VS2 | |
|