duplex filter, change-over | DSF 180-340 Imprimir Correo electrónico

notavailable_gb

Description:

Duplex filters of the series DSF 180-340 are suitable for a working pressure up to 25 bar.
Pressure peaks can be absorbed with a sufficient margin of safety.
A three-way-change-over valve which is integrated in the middle of the housing makes it possible to switch from the dirty filter-side to the clean filter-side without interruting operation.
The filters can be installed as suction filter, pressure filter or return-line filter.
The filter element consist of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to the inside. Filter finer than 40 µm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 µm(c) are available; finer filter elements on request.
INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life.
INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils.
Approvals according to TÜV, and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S.; P.R.S.;USS.R.S. and others are possible.
The internal valve is integrated in the filter. After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter.

folder_grey Instruction manual
Technical data:
temperature range: - 10 °C to + 80 °C (for a short time + 100 °C)
operating medium: mineral oil, other media on request
max. operating pressure: 25 bar
test pressure: 50 bar
connection system SAE-flange 3000 PSI or thread according to DIN 3852, T2
housing material: EN-GJS-400-18-LT
sealing material: Nitrile (NBR) or Viton (FPM),
other materials on request
installation position: vertical
Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3.
Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4).
folder_grey Data Sheet
folder_grey Brochure
folder_man Clogging Indicator:

visual AOR/AOC

visual-electrical AE

electronical VS1

electronical VS2

 