LF 1950-2200 Print E-mail
in-line filter

LF1950

Description:

In-line filters of the type LF 1950-2200 are suitable for a working pressure up to 32 bar.
Pressure peaks are absorbed with a sufficient margin of safety.
The filter is mounted in such a way that inlet and outlet are on the same level. It can be used as suction filter, pressure filter and return-line filter. The filter element consist of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to the inside.
For cleaning (see special leaflet 21070-4 resp. 39448-4) the mesh element respectively to change the glass fiber element remove the cover and take out the element.
Filter finer than 40 μm should use throw-away elements made of paper or Interpor fleece (glass fiber). Filter elements as fine as 5 μm(c) are available; finer filter elements on request.
INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirt retaining capacity and a long service life.
INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils
Approvals according to TÜV, and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible.
The internal valve is integrated in the filter cover. After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter.


folder_grey Instruction manual
Technical data:
temperature range: - 10 °C to + 80 °C (for a short time + 100 °C)
operating medium: mineral oil, other media on request
max. operating pressure: 16 bar
test pressure: 23 bar
connection system SAE-flange connection 3000 PSI
housing material: GGG 40.3
sealing material: Nitrile (NBR) or Viton (FPM),
other materials on request
installation position: vertical
mini-measuring connection:

G ¼

evacuation-or bleeder-connection: G ½
volume tank: LF 1950: 21,7 l
LF 2200: 22,0 l
Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3.
Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4).
folder_grey Data Sheet
folder_grey Brochure
folder_man Clogging Indicator:

visual OP

visual-electrical AE

visual-electrical OE

electrical VS1

electrical VS2