Description:

Duplex pressure filters with change-over valve type HDD are suitable for a working pressure up to 315 bar.
The pressure peaks are absorbed by a sufficient margin of safety. Duplex filters can be serviced without interruption of operation. The upper part has a three-way-change-over valve which allows to change-over the flow from the dirty filter-side to the clean filter-side without interrupting the operation. The change-over procedure does not lead to a cross sectional contraction. Prior to the change-over procedure a built-in pressure balance valve equalizes the housing pressure. After change-over the pressure balance valve is to be closed again. The closed filter-side has to be air-bled by vent V respectively by vent VI. Then change filter element. After screw in the filter bowl the pressure balance has to be opened shortly and the just serviced filter-side has to be air-bled. Filter elements are available down to a filter fineness of 4 µm(c).
INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirt retaining capacity and a long service life.
INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils.
INTERNORMEN-Filter elements are available with a pressure difference resistance up to Δp 160 bar and a rupture strength up to Δp 250 bar.
The internal valves are integrated into the centering pivot for the filter element. After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter. With the reverse valve a protection of the filter element is given when having a reverse flow inside the filter. The reverse flow will not be filtered.

folder_greyInstruction manual
Technical data:
temperature range:- 10 °C to + 80 °C (for a short time + 100 °C)
operating medium:mineral oil, other media on request
max. operating pressure:315 bar
test pressure:410 bar
connection system:thread connection according to ISO 228
housing material:C-steel
sealing material:Nitrile (NBR) or Viton (FPM),
other materials on request
installation position:vertical
air bleeding and mini-measuring connections dirt side:G ¼
measuring connections clean side:G ¾l
Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3.
Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4).
folder_greyData Sheet
folder_greyBrochure
folder_manClogging Indicator:

visual AOR/AOC

visual-electrical AE

electronical VS1