pressure filter, change-over | HDD 170-450 Print E-mail

pressure filter, change-over - HDD 170-450

Description:

Duplex pressure filters with change-over valve type HDD are suitable for a working pressure up to 315 bar.
The pressure peaks are absorbed by a sufficient margin of safety. Duplex filters can be serviced without interruption of operation. The upper part has a three-way-change-over valve which allows to change-over the flow from the dirty filter-side to the clean filter-side without interrupting the operation. The change-over procedure does not lead to a cross sectional contraction. Prior to the change-over procedure a built-in pressure balance valve equalizes the housing pressure. After change-over the pressure balance valve is to be closed again. The closed filter-side has to be air-bled by vent III respectively by vent IV. Then change filter element. After screw in the filter bowl the pressure balance has to be opened shortly and the just serviced filter-side has to be air-bled. Filter elements are available down to a filter fineness of 4 mm(c).
INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirt retaining capacity and a long service life.
INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils.
INTERNORMEN-Filter elements are available with a pressure difference resistance up to Δp 160 bar and a rupture strength up to Δp 250 bar.
The internal valves are integrated into the centering pivot for the filter element. After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter. With the reverse valve a protection of the filter element is given when having a reverse flow inside the filter. The reverse flow will not be filtered.

folder_greyInstruction manual
Technical data:
temperature range:- 10 °C to + 80 °C (for a short time + 100 °C)
operating medium:mineral oil, other media on request
max. operating pressure:315 bar
test pressure:410 bar
connection system:SAE-flange connection 6000 PSI
housing material:EN-GJS-400-18-LT; C-steel
sealing material:Nitrile (NBR) or Viton (FPM),
other materials on request
installation position:vertical
mini-measuring connections:G ¼
air bleeding connections:G ¾l
Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3.
Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4).
folder_greyData Sheet
folder_greyBrochure
folder_manClogging Indicator:

visual AOR/AOC

visual-electric AE

electronical VS1