pressure filter, change-over | DU 631-1950 Print E-mail

pressure filter, change-over - DU 631-1950

Description:

Pressure filters, change-over series DU 631-1950 are suitable for operating pressure up to 32 bar.
Pressure peaks can be absorbed with a sufficient margin of safety.
A three-way-change-over valve which is, integrated in the middle of the housing, makes it possible to switch from the dirty filter- side to the clean filter-side without interrupting operation.
These filters can be installed as suction filters, pressure filters or return-line filters.
The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to the inside.
Filter finer than 40 μm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 μm(c) are available; finer filter elements on request.
INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirt-retaining capacity and a long service life.
INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils.
Approvals according to TÜV, and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible.
The internal valve is integrated in the filter cover. After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter.

folder_greyInstruction manual
Technical data:
temperature range:- 10 °C to + 80 °C (for a short time + 100 °C)
operating medium:mineral oil, other media on request
max. operating pressure:32 bar
test pressure:64 bar
connection systemSAE-flange connection 3000 PSI
housing material:EN-GJS-400-18-LT
sealing material:Nitrile (NBR) or Viton (FPM),
other materials on request
installation position:vertical
mini-measuring connections:G ¼
evacuation-or bleeder connections:G ½
volume tank DU 631:2x 5,7 l
DU 1001:2x 13 l
DU 1950:2x 23,3 l
Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3.
Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4)
folder_greyData Sheet:
folder_greyBrochure
folder_manClogging Indicator:

visual-electrical AE

electronical VS1

electronical VS2

 