duplex filter | DSF 1201-10001 |
|
|
|

|
Description:
Duplex filters of the seriesDSF1201 - 10001 are suitable for a working pressure up to 16 bar. Pressure peaks can be absorbedwitha sufficient margin of safety. Four mechanicallyconnectedchange-over flaps enabling the change-over withoutservice-interruptionfrom the clean to the dirty filter-side. The filters can be installedassuction filter, pressure filter or return-line filter. The filter element consistofstar-shaped, pleated filter material which is supported on theinsideby a perforated core tube and is bonded to the end caps withahigh-quality adhesive. The flow direction is from outside totheinside. Filter finer than 40 μm should use throw-awayelementsmade of paper or Interpor fleece (glass fibre). Filter elementsas fineas 5 μm (c) are available; finer filter elements onrequest. INTERNORMEN-Filter elementsareknown as elements with a high intrinsic stability and anexcellentfiltration capability, a high dirt-retaining capacity and alongservice life. INTERNORMEN-Filter are suitableforall petroleum based fluids, HW-emulsions, most synthetichydraulicfluids and lubrication oils. Approvals according toTÜV,and the major „Shipyard ClassificationSocieties“D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S.;P.R.S.;USS.R.S. and othersare possible.
|
 |
Instruction manual |
| Technical data: |
|
|
|
| temperature range: |
- 10 °C to + 80°C(for a short time + 100 °C) |
| operating medium: |
mineral oil, other media on request |
| max. operating pressure: |
16 bar |
| test pressure: |
23 bar |
| connection system |
flange connection DIN 2633, 16 bar |
| housing material: |
C-steel |
| sealing material: |
Nitrile (NBR) or Viton (FPM), other materials on request |
| installation position: |
vertical |
| mini-measuring connection: |
G ¼ |
|
|
|
|
|
|
|
|
Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no.34279-4).
|
 |
Data Sheet |
 |
Brochure |
 |
Clogging Indicator: |
|
visual OP
visual-electrical AE
visual-electrical OE
electronical VS1
electronical VS2
|
|
|