pressure filter change-over, according to ASME-code | DA 1015 Print E-mail

notavailable_gb

Description:

Pressure filters, change-over series DA 1015 are suitable for operating pressure up to 40 bar. Pressure peaks can be absorbed with a sufficient margin o safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outs ide to the inside. These filters can be installed as suction filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 μm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 μm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. The inspection according to TÜV, according to ASME VIII Div.1 and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. If inspection is required please indicate in your order.

 

 

folder_grey Instruction manual
Technical data:
temperature ranges
- calculation temperature: - 10°C to +100°C
- medium temperature: - 10°C to +80°C
- ambient temperature: - 40°C to +60°C
- survival temperature: - 40°C to +100°
operating medium: mineral oil, other media on request
max. operating pressure: 40 bar
test pressure acc. to PED 97/23/EC: 1,43 x operating pressure = 57 bar
test pressure acc. to ASME VIII Div. 1: 1,3 x operating pressure = 52 bar
test pressure acc. to API 614, Chapter 1: 1,5 x operating pressure = 60 bar
connection system: SAE-flange connection 3000 PSI
housing material: steel
sealing material: Nitrile (NBR) or Viton (FPM),
other materials on request
installation position: vertical
bleeder connection: NPT ½“ and SAE ¾“ 3000 PSI
drain connection dirt side: NPT ½“ and SAE ¾“ 3000 PSI
drain connection clean side: NPT ½“
volume tank: 2x 19 l
Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3.
Classified under ATEX Directive 94/9/EC according to specificapplication (see questionnaire sheet-no. 34279-4).
folder_grey Massblatt
folder_grey Broschüre
folder_man Verschmutzungs-anzeiger:

optisch-elektrisch AE

optisch-elektrisch OE

optisch OP

optisch AOR/AOC

elektronisch VS1

elektronisch VS2