pressure filter change-over, according to ASME-code | DA 1004 |
|
|
|

|
Description:
Pressure filters, change-over series DA 1004 are suitable for operating pressure up to 40 bar. Pressure peaks can be absorbed with a sufficient margin o safety. Change-over ball valve which, integrated in the middle of the housing, makes it possible to switch from the dirty filter-side to the clean filter-side without interrupting operation. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outs ide to the inside. These filters can be installed as suction filters. For cleaning (see special leaflet 21070-4 and 34448-4) the mesh element respectively to change the glass fibre element remove the cover and take out the element. Filter finer than 40 μm should use throw-away elements made of paper or Interpor fleece (glass fibre). Filter elements as fine as 5 μm(c) are available; finer filter elements on request. INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. The inspection according to TÜV, according to ASME VIII Div.1 and the major „Shipyard Classification Societies“ D.N.V.; B.V.; G.L.; L.R.S.; R.I.N.A.; A.B.S. and others are possible. If inspection is required please indicate in your order.
Â
Â
|
 |
Instruction manual |
| Technical data: |
|
|
|
| temperature ranges |
|
| - calculation temperature: |
-10°C to +100°C |
| - medium temperature: |
-10°C to +80°C |
| - ambient temperature: |
-40°C to +60°C |
| - survival temperature: |
-40°C to +100° |
| operating medium: |
mineral oil, other media on request |
| max. operating pressure: |
40 bar |
| test pressure acc. to PED 97/23/EC: |
1,43x operating pressure = 57 bar |
| test pressure acc. to ASME VIII Div. 1: |
1,3x operating pressure = 52 bar |
| test pressure acc. to API 614, Chapter 1: |
1,5x operating pressure = 60 bar |
| connection system: |
SAE-flange connection 3000 PSI |
| housing material: |
steel |
| sealing material: |
Nitrile (NBR) or Viton (FPM), other materials on request |
| installation position: |
vertical |
| bleeder connection: |
NPT ½“ and SAE ¾“ 3000 PSI |
| drain connection dirt side: |
NPT ½“ and SAE ¾“ 3000 PSI |
| drain connection clean side: |
NPT½“ |
| volume tank: |
2x 19 l |
|
|
Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specificapplication (see questionnaire sheet-no. 34279-4)
|
 |
Data Sheet |
 |
Brochure |
 |
Clogging Indicator: |
|
visual-electrical AE
visual-electrical OE
visual OP
visual AOR/AOC
electronical VS1
electronical VS2
|
|
|