Home Imprint Sitemap Contact Addresses
Deutsch (Deutschland)English (United Kingdom)American EnglishFrench (Fr)Español(Spanish Formal International)Russian(RU)Chinese

Upcoming fairs

No current events.

pressure filter, manifold mounted | HPP 60-450 Print E-mail
pressure filter, manifold mounted

pressure filter, manifold mounted - HPP 60-450

Description:

Pressure filter of the series HPP 60-450 are suitable for a working pressure up to 315 bar.
The pressure peaks are absorbed by a sufficient margin of safety. The HPP-filters are flanged to the mounting-surface.
The filter element consist of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to the inside.
Filter elements are available down to 4 µm(c).
INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirt retaining capacity and a long service life.
INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils.
INTERNORMEN-Filter elements are available up to a pressure difference resistance of ∆p 160 bar and a rupture strength of ∆p 250 bar.
The internal valves are integrated into the centering pivot for the filter element.
After reaching the opening pressure the by-pass valve causes that an unfiltered partial flow passes the filter. With the reverse valve a protection of the filter element is given when having a reverse flow inside the filter. The reverse flow will not be filtered.


 

folder_grey Instruction manual
Technical data:
temperature range: - 10 °C to + 80 °C (for a short time + 100 °C)
operating medium: mineral oil, other media on request
max. operating pressure: 315 bar
test pressure: 410 bar
connection system manifold mounted
housing material: C-steel
sealing material: Nitrile (NBR) or Viton (FPM),
other materials on request
installation position: vertical
Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3.
Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4).
folder_grey Data Sheet
folder_grey Brochure
folder_man Clogging Indicator:

visual-electrical AE

visual AOR/AOC

electronical VS1

electronical VS2

 
FacebookYouTube