battery-pressure filter | BHP |
|
|
|

|
Description:
The filter-batteries of the series BHP are suitable for the filtration of large flow volumes up to a working pressure of 315 bar and are stressing a high filter efficiency. The filters of the filter-battery consist of spheroidal graphite cast iron (EN-GJS-400-18-LT) respectively of C-steel. For changing the filter elements the filter tubes have to be opened at the tube plug (bottom part of the filter). Filter elements are available down to a filter fineness of 4μm(c). INTERNORMEN-Filter elements consist of filter materials with a high intrinsic stability, an excellent particle retention, respectively a high dirt holding capacity and provide a long service life. INTERNORMEN-Filters can be used for mineral oil based fluids, HW-emulsions, water glycols, most synthetic hydraulic fluids and lubrication fluids. INTERNORMEN-Filter elements are available with a pressure difference resistance up to Δp 160 bar and a rupture strength up to Δp 250 bar. The internal valves are integrated into the centering pivot for the filter element. After reaching the by-pass valve causes that an unfiltered partial flow passes the filter. With the reve rse valve a protection of the filter element is given when having a reverse flow inside the filter. The reverse flow will not be filtered.
|
 |
Instruction manual |
| technical data: |
|
| |
|
| temperature range: |
- 10 °C to + 80 °C (for a short time + 100 °C) |
| operating medium: |
mineral oil, other media on request |
| max. operating pressure: |
315 bar |
| test pressure: |
410 bar |
| connection system: |
SAE-flange connection 6000 PSI, |
| |
AVIT-flange connection 320 bar |
| air bleeding and mini-measuring connection: |
G ¼ |
| contents: |
BHP 2x901 = 8 l |
|
BHP 3x901 = 18 l |
|
BHP 4x901 = 24 l |
|
BHP 5x901 = 30 l |
|
BHP 6x901 = 36 l |
|
BHP 7x901 = 42 l |
| |
|
| |
|
|
|
| |
|
Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4).
|
 |
Data Sheet |
 |
Brochure |
 |
Clogging Indicator: |
| |
visual AOR/AOC
visual-electrical AE
electrical VS1
electrical VS2
|
| |
|